Heating & Air Conditioning in Weaverville, NC
Weaverville’s First Choice for Complete HVAC Service
For exceptional heating, air conditioning and indoor air quality services in Weaverville, NC, call Comfort Central, Inc. Our professional, extensively trained HVAC service technicians have all the knowledge and experience necessary to ensure your home is kept comfortable throughout the entire year.
From complete installations to system maintenance and repair services, our experienced and fully certified service technicians are qualified to handle any service that you may need. Your comfort is our business, and your satisfaction our guarantee!
To schedule an air conditioning or heating service in Weaverville, NC today, call Comfort Central, Inc. at 828-483-4040 or request an estimate online.
Recent Jobs and Reviews in Weaverville, NC
Customers say: The reviews exhibit a positive sentiment towards Comfort Central A/C. Customers consistently praise the company's services, highlighting their punctuality, professionalism, and expertise. They express gratitude for the technicians' knowledge, courtesy, and efficiency, as well as their ability to explain technical issues in a clear and understandable manner. Customers also appreciate the company's reliability, with many indicating that they have used Comfort Central for years and trust their services. Additionally, the technicians are described as friendly, polite, and accommodating, going above and beyond to ensure customer satisfaction. The positive sentiment is further reinforced by customers' willingness to recommend Comfort Central to others and their satisfaction with the company's value for money. Overall, the reviews convey a sense of trust, reliability, and satisfaction with Comfort Central A/C's services.
Our Local Reviews by City
- Alexander, NC (1)
- Arden, NC (7)
- Asheville, NC (83)
- Biltmore Forest, NC (2)
- Black Mountain, NC (6)
- Brevard, NC (78)
- Cedar Mountain, NC (2)
- Clyde, NC (1)
- Etowah, NC (14)
- Fairview, NC (9)
- Flat Rock, NC (11)
- Fletcher, NC (8)
- Hendersonville, NC (42)
- Horse Shoe, NC (3)
- Lake Junaluska, NC (1)
- Lake Toxaway, NC (6)
- Laurel Park, NC (5)
- Leicester, NC (2)
- Lower Hominy, NC (1)
- Maggie Valley, NC (3)
- Mills River, NC (7)
- Penrose, NC (10)
- Pisgah Forest, NC (33)
- Rosman, NC (3)
- Saluda, NC (1)
- Sapphire, NC (4)
- Waynesville, NC (4)
- Weaverville, NC (9)
- Woodfin, NC (3)
- Zirconia, NC (2)
Job Locations and Reviews
Found furnace off on three attempts hard lockout. Tested DC voltage on flame sensor 12.5 DC. Recheck and wire brushed burners and flame sensor. Fire didn’t look like it had a lot of force on it. So I checked gas pressure gas pressure was 1.5 ic. Adjusted gas valve to 3.5.Ic. Tested temperature difference. 60° don’t see any other issues besides the gas pressure that could’ve caused this thing not to fire and lock out.
Replaced blower motor under manufacturers warranty and cycled system to check operation.
Found system emergency heat button pressed on zone control - took out of that function and cycled heat pump in first and second stages to check operation. Did cursory cleaning of furnace burners and flame sensor and cycled furnace to ensure system lights off properly every time.
Found system drain pipe frozen outside causing unit to shut off on pressure switch fault. Removed drain blockage and removed coupling that was causing drain to freeze. Cycled system to check operation. Everything runs normally.
Found spring on damper actuator to be bad. Must replace the damper replaced damper for upstairs tested it no issues found. Found a 16 x 20 x 5 Honeywell filter in a 16 x 20 x 5 filter box. Which is pulling air from the attic into the system will need a 16 x 20 x 5 filter Honeywell replacement filter code FC10081003.
Replaced leaking radiator in rom by laundry room
Was told blower would go on and off every 15 to 30 seconds. Turned on fan at tstat. No issues. Turned on heat. No issues found. Check float switches and wire connections. Cycled system above and below room temp 10 times trying to reproduce the same issue. Each time blower worked s designed. If it happens again, give us a call and we may have to replace the blower motor.
Performed heating maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown. Changed customer provided filter - flushed drain. Everything looks and runs great!
Replace T6 dual fuel thermostat reprogram thermostat. Set balance point at 35°. Tested heat pump. Raised lockout temperature to 60 tested heat. Furnace came on. Reset balance point to 35 no other issues found.
Replacement of burners and cycling of system to check operation - reduced LP gas pressure from 15" w c. To 11.5" for more efficient burn - cycled system to make sure system lights off every time. Everything looks and runs great!
Found furnace burners are in rough shape and should be replaced. Will call with pricing and availability.
Performed heating maintenance tune up service on gas furnace system checking all electrical components including furnace safeties, performed full combustion analysis checking, CO, CO2, O2, Flue gas temperature, gas pressure, draft. Cleaned furnace burners, flame sensor, flushed drains, traps, collector box, checked furnace filter, treated condensate pump.
Performed heating maintenance tune up service on dual fuel furnace and heat pump system checking all electrical components, refrigerant balance, unit start up, light off, operation, shutdown, performed full combustion analysis of system checking CO, CO2, O2, Flue gas temperature, gas pressure, system safeties, flushed system drains, collector box, traps, treated condensate pump. Found system balance point effected by outdoor temperature sensor failing open not allowing unit to switch between heat pump to furnace. Will order and replace temperature sensor under warranty.
6" start collar had been slightly crushed pulling collar away from trunk box. Bent out start collar and refitted into trunk and sealed penetration. Cycled system on fan high to check operation and for duct leakage. Everything operates normally again.
System air handler in crawlspace made inaccessible by deck joist crossing in front of crawlspace door that swings out. System cannot be fully inspected until crawlspace is accessible. Recommend potentially making door swing into the crawlspace as potential solution. Would be happy to reschedule and complete service once crawlspace is accessible again. Outdoor unit (heat pump condenser) otherwise operates normally.
Replacement of thermostats with Honeywell T6 WiFi thermostats. Performed heating maintenance tune up service on both geothermal systems checking all electrical, refrigerant balance, unit start up, operation, shutdown, geothermal loop and pumps. Everything looks and runs great!
Ultimate Heating Tune-Up Gas Heat: serviced and inspected gas heating system checking air flow, temperature rise, electrical, gas pressure, safeties, controls and limits, heat exchanger and venting. cleaned and checked system components to manufacturer specifications and performed combustion inspection. Pressure gauge no showing pressure so I added pressure with pressure reducing valve and still didn’t move. Don’t think it will be a issue as it only reads pressure and doesn’t control the pressure in the boiler
Found new radiator by laundry room leaking at top compression fitting 3rd in from right. Can’t tighten bolts because lack of space between radiator and nut to get wrench or ratchet on. Will look into if it’s under warranty and availability. Ball valves for radiator and basement were closed to prevent more water leakage. Once the pressure in the radiator equalizes it should stop leaking being that the leak is on top of the radiator sections.
Found 2nd floor air handler circuit board melted along with the majority of all the high and low voltage wires. Replaced board replaced burnt and melted wires. found thermostat to be shorted. Replace thermostat. Tested amp draw of blower motor tested operation. Blower was pulling 1.5 a Everything is running as it should
Replacement of outdoor unit electrical panel under warranty and cycling of system to check operation. Everything looks and runs great!
E100V Dehumidifier #8190FF Ventilation Plenum Wall Bracket Installation shall include: Equipment specified above plus materials and labor to include: • Required Electrical is included. • This system will be a stand alone installation for the basement. Supply duct and return will be in the finished area with a small supply and return in the storage area of the basement. • All work will be completed in a professional workmanlike manner. • AprilAire Manufacturer’s Warranty: Five (5) Year Limited Parts. • One (1) Year Labor Warranty Provided by Comfort Central, Inc
Found system low on refrigerant r410a - system outdoor coils impacted - cleaned coils and performed halogen leak search - found system evaporator coil leaking on front right side of coil. Recommend replacement of coil. Charged unit to provide cooling in interim while awaiting pricing and availability of new coil. Will call with pricing and availability to replace evaporator coil.
2-Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Replaced batteries in basement sensor. Tested dehumidifier. Inlet- 59%. Outlet-22%. Couldn’t find any issues with dehumidifier No issues found today.
No cooling - found outdoor disconnect flipped to off - found outdoor unit flat on refrigerant - probably why unit disconnect was turned off. Recommend replacement of system. Don't believe system will hold a recharge. System is 24 years old and runs off r-22 refrigerant. See attached tag for outdoor unit for unit model and serial. Scheduled estimate for replacement Tuesday.
Performed AC cooling tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor units, treatment of drain line. Everything looks and runs great!